Honeywell Dial Set Chronotherm Manual Meat

Honeywell Dial Set Chronotherm Manual Meat

Honeywell Dial Set Chronotherm Manual Meat Average ratng: 9,3/10 9568 reviews

The round manual thermostat by Honeywell is the world's most popular thermostat - installed in over 70 million homes and buildings. Rapidshare This CT87N heating and cooling model provides precise accurate performance with the ease of use that you've grown accustomed to - simply turn the dial to desired temperature and let the thermostat take over.

Honeywell Dial Set Chronotherm Manual Meat

• T8602C Chronotherm® IVDeluxe ProgrammableThermostatsINSTALLATION INSTRUCTIONSAPPLICATIONThe T8602 Chronotherm ® IV Deluxe Programmable Thermostat provides electronic control of 24 Vac single-stageheating and cooling systems or 750 mV heating system. Refer to Table 1 for a general description of the thermostat. AllT8602 thermostats are powered by batteries.Table 1.

Description of T8602 Thermostats. • T8602C CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATSNOYESNO5 FEET[1.5 METERS]NOM10106Fig. Typical location of thermostat.1.2.3.4.5.6.WIRINGPosition and level the wallplate (for appearanceonly). The thermostat functions correctly evenwhen not level.Use a pencil to mark the mounting holes.See Fig. 2.Remove the wallplate from the wall and drill two3/16 inch (76 mm) holes in the wall (if drywall) asmarked.

Honeywell

For firmer material such as plaster, drilltwo 7/32 inch (5. • T8602C CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATSTHERMOSTATYOGBWTHERMOSTATRRCOTYOTGOBWROTCOMPRESSORCONTACTORCOOLDAMPERFANRELAYPILOTSTATCONTROL(IF USED)HEATRELAY2OT13OUTDOORTEMPERATURESENSORTHTH/PPHEATDAMPERPP2MILLIVOLTAGEGENERATOR1L1(HOT)1L2LIMITCONTROLOUTDOORTEMPERATURESENSORMILLIVOLTAGEGAS CONTROLAVAILABLE ON SELECT MODELS. OT WIRES MUST HAVE ASEPARATE CABLE FROM THE THERMOSTAT CABLE. • T8602C CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATSUsing Thermostat Keys• configure Installer Setup,• check Self-Test,• display outdoor temperature (select models),The thermostat keys are used to:• set current day and time,• program times and setpoints for heating and cooling,• temporarily override program temperatures,• display present setting,See Fig.

9 for location of the keys.NOTE: Always press the keys with your fingertip orsimilar blunt tool. • T8602C CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATSFAN OPERATION SWITCHThe thermostat fan operation switch, labeled FUELSWITCH in Fig. 11 is factory set in the F position. This isthe correct setting for most systems. If your system is anelectric heat system, set the switch to E. The E settingallows the fan to turn on immediately with the heating orcooling in a system where the G terminal is connected.— To advance to the next Installer Setup, press theTime ∆ key. • T8602C CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATSTable 3.

Crack serial keygen. Take Train Simulator 2014 cd key generator for free and play in Cracked Train Simulator 2014 pc.

Thermostat Installer Setup Options.SelectNot Used.Heating cyclerate.Not Used. • T8602C CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATSTable 3.

Thermostat Installer Setup Options. (Continued)Installer SetupNumber (PressTime ∆ key tochange)DisplayTemperaturedisplayadjustment.370Furnace AirFilter Timer.43290 days (calendar 0, 1, 3, 4days)0 – off1 – 30 days3 – 180 days4 – 365 days(Time is counted by calendardays in any mode.)Humidifier PadMonitor.440Off1, 2, 31 – 90 days2 – 180 days3 – 365 days(Time is counted by calendardays in heat mode. • T8602C CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATSSetting Current Day and Time1.Press Set Current Day/Time.Set Day/TimeNOTE: On initial powerup or after an extended powerloss, 1:00 pm flashes on the display until akey is pressed.AMDaylightTimeTimeRunProgramHold TempSet CurrentDay/TimeLeaveReturnSleepSystemHeat/CoolSettingsDayDaylightTimeSet ProgramWakeFanTueDSTCopyM146224.Press Run Program. • T8602C CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATSINSTALLER SYSTEM TESTUse the Installer System Test to check the thermostatoperation. Refer to Table 4 for a list of the availablesystem tests.Wait Set Program Set Day/Time Temporary SettingRecoveryHold forCAUTIONAMPMSystemHeatOffCoolDaysMon Tue Wed Thu Fri Sat Sun Repl Batt RoomHeat CoolWake Leave Return Sleep DSTEquipment Damage Hazard.Minimum compressor off-time is bypassedduring Installer System Test. • T8602C CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATSTHERMOSTAT INFORMATION1.Press the Time ∆ key to access the thermostatinformation.2.Press the increase key to display the productiondate code. The first two large digits are the monthand the third digit is the last digit of the year.(Example: 027 = February 1997).4.Press the increase key again to display the software revision number.(Example: 001 = Revision number 1).5.

Honeywell Dial Set Chronotherm Manual Meat
© 2019